Customization: | Available |
---|---|
Power: | Hydraulic |
Precision Control: | Custom Design |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Performance data:
ITEM | MODEL FF-130 | |
SUPPLY PRESSURE[MPa] | 2~28 | |
RATED SUPPLY PRESSURE Ps[MPa] | 21 | |
RATED FLOW Qn[L/min] | 40,50, 60 | |
RATED CURRENT In [mA] | 40 | |
HYSTERESIS [ % ] | ≤4 | |
THRESHOLD [ % ] | ≤1 | |
LINEARITY[ % ] | ≤7.5 | |
SYMMETRY[ % ] | ≤10 | |
PRESSURE GAIN[%Ps/1% In] | >30 | |
INTERNAL LEAKAGE[L/min] | ≤2 | |
NULL BIAS[ % ] | ≤±3 | |
NULL SHIFT WITH TEMPERATURE[ % ] | ≤5 | |
FREQUENCE RESPONSE | AMPLITUDE RATIO WITH (-3dB)[ Hz ] | ≥100 |
PHASE LAG WITH (-90°)[ Hz ] | ≥100 | |
WORKING TEMPERATURE[ ºC ] | -30~ +135 | |
NET WEIGHT[ kg ] | 0.60 |
RESISTANCE OF EACH COIL AT 20ºC(Ω) | RATED CURRENT (mA) | PROXIMATE COIL INDUCTANCE(H) | ||||
Differential, parallel or individual coils | series | differential | series | individual | parallel | |
80 | 40 | 20 | 0.98 | 2 | 0.58 | 0.5 |