Performance data:
ITEM | MODEL FF-115/12 | MODEL FF-115/40 | MODEL FF-115/75 | MODEL FF-115A/9 | MODEL FF-115A/37 | MODEL FF-115A/75 | |
RATED SUPPLY PRESSURE Ps[MPa] | 21 | 21 | 21 | 21 | 21 | 21 | |
RATED FLOW Qn[L/min] | 12 | 40 | 75 | 9 | 37 | 75 | |
RATED CURRENT In [mA] | 10 | 10 | 10 | 30 | 30 | 30 | |
COIL RESISTANCE[ Ω ] | 1000 | 1000 | 1000 | 400 | 400 | 400 | |
HYSTERESIS [ % ] | ≤4 | ≤4 | ≤4 | ≤4 | ≤4 | ≤4 | |
THRESHOLD [ % ] | ≤1 | ≤1 | ≤1 | ≤1 | ≤1 | ≤1 | |
LINEARITY[ % ] | ≤7.5 | ≤7.5 | ≤7.5 | ≤7.5 | ≤7.5 | ≤7.5 | |
SYMMETRY[ % ] | ≤10 | ≤10 | ≤10 | ≤10 | ≤10 | ≤10 | |
PRESSURE GAIN[%Ps/1% In] | >30 | >30 | >30 | >30 | >30 | >30 | |
INTERNAL LEAKAGE[L/min] | 1.3 | 2.4 | 4 | 1 | 2 | 4 | |
NULL BIAS[ % ] | -3~+3 | -3~+3 | -3~+3 | -2~+2 | -2~+2 | -2~+2 | |
NULL SHIFT WITH SUPPLY PRESSURE (80~110% Ps)[ % ] | ≤±2 | ≤±2 | ≤±2 | ≤±2 | ≤±2 | ≤±2 | |
NULL SHIFT WITH RETURN PRESSURE (2~20% Ps)[ % ] | ≤±2 | ≤±2 | ≤±2 | ≤±2 | ≤±2 | ≤±2 | |
NULL SHIFT WITH TEMPERATURE (-10~ +60 ºC)[ % ] | ≤±2 | ≤±2 | ≤±2 | ≤±2 | ≤±2 | ≤±2 | |
AMPLITUDE RATIO WITH (-3dB)[ Hz ] | ≥50 | ≥50 | ≥50 | ≥50 | ≥50 | ≥50 | |
PHASE LAG WITH (-90°)[ Hz ] | ≥50 | ≥50 | ≥50 | ≥50 | ≥50 | ≥50 |