Customization: | Available |
---|---|
Power: | Hydraulic |
Precision Control: | Custom Design |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Performance data:
ITEM | MODEL FF-113/95 | MODEL FF-113/150 | MODEL FF-113/230 | |
RATED SUPPLY PRESSURE Ps[MPa] | 21 | 21 | 21 | |
RATED FLOW Qn[L/min] | 95 | 150 | 230 | |
RATED CURRENT In [mA] | 40 | 15 | 40 | |
INTERNAL LEAKAGE[L/min] | 7 | 7 | 10 | |
NULL BIAS[ % ] | -3~+3 | -3~+3 | -3~+3 | |
COIL RESISTANCE[ Ω ] | 80 | 200 | 80 | |
PHASE LAG WITH (-90°)[ Hz ] | ≥40 | ≥30 | ≥30 | |
WORKING TEMPERATURE[ ºC ] | -30~ +100 | -30~ +100 | -30~ +100 |
RESISTANCE OF EACH COIL AT 20ºC(Ω) | RATED CURRENT (mA) | PROXIMATE COIL INDUCTANCE(H) | ||||
Differential, parallel or individual coils | series | differential | series | individual | parallel | |
80 | 40 | 20 | 0.98 | 2 | 0.58 | 0.5 |
200 | 15 | 7.5 | 2.41 | 5 | 1.8 | 1.5 |