Customization: | Available |
---|---|
Precision Control: | Custom Design |
High Contamination Resistance: | Direct Drive Servo Valve |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Performance data:
ITEM | MODEL FF-133/5 | MODEL FF-133/10 | MODEL FF-133/20 | MODEL FF-133/40 | |
POWER SUPPLY | ±24 V DC | ±24 V DC | ±24 V DC | ±24 V DC | |
RATED INPUT SIGNAL | ±10 V | ±10 V | ±10 V | ±10 V | |
FLUID | YH-10,YH-12 OR OTHER PETROL BASED HYDRAULIC FLUID | ||||
SUPPLY PRESSURE[MPa] | 2~28 | 2~28 | 2~28 | 2~28 | |
RATED SUPPLY PRESSURE Ps[MPa] | 21 | 21 | 21 | 21 | |
RATED FLOW[L/min]P=7MPa | 5±0.5 | 10±1 | 20±2 | 40±4 | |
LAP | -2.5%~ +2.5% | -2.5%~ +2.5% | -2.5%~ +2.5% | -2.5%~ +2.5% | |
HYSTERESIS [ % ] | ≤0.5 | ≤0.5 | ≤0.5 | ≤0.5 | |
THRESHOLD [ % ] | ≤0.2 | ≤0.2 | ≤0.2 | ≤0.2 | |
LINEARITY[ % ] | ≤7.5 | ≤7.5 | ≤7.5 | ≤7.5 | |
SYMMETRY[ % ] | ≤10 | ≤10 | ≤10 | ≤10 | |
PRESSURE GAIN[%Ps/1% In] | ≥30 | ≥30 | ≥30 | ≥30 | |
INTERNAL LEAKAGE[L/min]P=14 MPa | ≤0.15 | ≤0.30 | ≤0.60 | ≤1.20 | |
NULL BIAS[ % ] | ≤±2 | ≤±2 | ≤±2 | ≤±2 | |
ENVIRONMENT TEMPERATURE [ ºC ] | -20~+60 | -20~+60 | -20~+60 | -20~+60 | |
FLUID TEMPERATURE[ ºC ] | -20~+80 | -20~+80 | -20~+80 | -20~+80 | |
FREQUENCY P=14 Mpa | AMPLITUDE RATIO WITH (-3dB)[ Hz ] | ≥50 | ≥50 | ≥50 | ≥50 |
PHASE LAG WITH (-90°)[ Hz ] | ≥50 | ≥50 | ≥50 | ≥50 | |
NET WEIGHT[ kg ] | 2.75 | 2.75 | 2.75 | 2.75 |
A | POWER SUPPLY +24V DC(22V DC~28V DC) | ||||
B | POWER SUPPLY (0 V ) | ||||
C | NOT APPLICABLE | ||||
D | COMMAND SIGNAL 0~10±V DC, OUTPUT IMPEDANCE= 50KΩ | ||||
E | REVERSE COMMAND SIGNAL 0~10±V DC, OUTPUT IMPEDANCE= 50KΩ | ||||
F | OUTPUT SIGNAL MONITORING SPOOL POSITION, LOAD IMPEDANCE(VISUS 0V) RANGE 300~500Ω |